PHiliph Goldway G30 Patient Monitor NIBP Board C-NIBP312B 89-83-16 V1 For Hosptail

Brand Name : PHiliph

Model Number : Goldway G30 patient monitor

Certification : CE/CB/ROSH

Place of Origin : USA

MOQ : 1

Price : USD

Payment Terms : L/C, D/A, D/P, T/T

Packaging Details : Carton

Brand : Goldway G30 patient monitor NIBP Board

Color : Green

Material : NIBP Board

Wattanty : 90 Days

Packing weight : 1.5Kg

size : Machine size

Application area : Monitor Machine

Condition : used or new

Estimated Ship Time : 3-5 Business Days

Depth0 : 12cm

Width : 12cm

Height : 9cm

net weight : 0.3kg

Shape : cuboid

Contact Now

PHiliphh Goldway G30 patient monitor NIBP Board C-NIBP312B 89-83-16 V1

►Quick Detail:

Thank you for browsing our company's products, this NIBP board is compatible with PHiliphh Goldway G30 patient monitor.

After powering on, the instrument performs self-test for a few seconds, and then the fault information code "NIBPHWERR06" appears. There are no NIBP markers on the display screen.

When the fault occurs, use a multimeter to measure the output of A4D to be +12V. The output of A1A is abnormal, which prevents the CPU from providing +15V voltage to the D/A converter. The D/A converter does not work, NIBP does not work, and there is nothing on the display screen. Any NIBP marker. It was initially concluded that A4 was partially damaged. After replacing the A4 quad op amp LM348, the fault still existed when the machine was turned on again, indicating that there was no problem with A4. Then carefully check the voltage value of the peripheral circuit of the line and the related resistance and capacitance values, all of which are normal. Further test the online resistance of pressure sensor B1 and found that the pressure sensor was faulty. If the NIBP board fails, you need to replace another NIBP board, which is relatively expensive.

PHiliph Goldway G30 Patient Monitor NIBP Board C-NIBP312B 89-83-16 V1 For Hosptail

PHiliph Goldway G30 Patient Monitor NIBP Board C-NIBP312B 89-83-16 V1 For Hosptail

Fault analysis and maintenance

The monitor is composed of the main CPU board, image control board, NIBP board, ECG preamplifier board and power board. According to the fault information code, the fault mainly occurs on the NIBP board. The pressure sensor B1 in the NIBP board is responsible for blood pressure detection and inflation and deflation control functions of the blood pressure measurement cuff. The signal from the pressure sensor B1 passes through the preamplifier, zero controller and gain amplifier and then the output signal reaches the analog mixer in two ways for blood pressure measurement and cuff inflation and deflation control. According to the screen fault message "NEBPHWERR06".
It means that the fault is in a certain link of the "PRESSUREDCCHANNEL" channel. A5A and A5B form a constant current source. When the line is working normally, there is a +12V voltage at both ends of the test points X8/8 and X8/7, which is added to both ends of the R5 resistor to generate a 4mA constant current source. A5C and A5D are the zeroing circuits of bridge B1, providing two sets of +5VR and -10VR power supplies. After the signal is pre-amplified and filtered by zero adjustment, the A4D output value is about -5V. The A4D output signal is added to the input terminal P-ON of the pressure control switch circuit A1A. When the P-ON point is about -5V, the output of A1A causes the CPU (8051) to connect the +15VD working voltage of the D/A, and the instrument displays NIBP works fine.

►Product parameters:

Be applicable: PHiliphh Goldway G30 patient monitor NIBP Board
Model: NIBP Board C-NIBP312B 89-83-16 V1
Material: Polymer materials, metal materials, ceramic materials and nanomaterials
MOQ: one piece
Imported product registration standards: YZB/GER 1059-2011 "Defibrillator"
Application scope: ICU, private clinic, hospital
Working humidity:

10%~90%

Package: Safe BOX packaging

About delivery:

We default to express delivery by DHL. We will contact you as soon as possible when sending express delivery. If you have any questions after receiving the express delivery, please feel free to contact us at any time.

►FAQ:

1. Does your company have catalogs and price lists for all its products?

terribly sorry. Please check our website and send me the model number or pictures, we will provide you with the latest quotation of the product at any time.

2. How long is the warranty period?

90 days

3. How long will it take for me to receive the ordered products after purchasing them?

It usually takes about 5-7 working days to reach you



Product Tags:

C-NIBP312B Patient Monitor NIBP Board

      

Goldway G30 Patient Monitor NIBP Board

      
Quality PHiliph Goldway G30 Patient Monitor NIBP Board C-NIBP312B 89-83-16 V1 For Hosptail wholesale

PHiliph Goldway G30 Patient Monitor NIBP Board C-NIBP312B 89-83-16 V1 For Hosptail Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: China World Technology Medical Equipment Service Group
*Subject:
*Message:
Characters Remaining: (0/3000)